Harvey'S 018210-24 Pvc Heavy Body Cement 8 Oz., Clear

buy solvents & sealers at cheap rate in bulk. wholesale & retail plumbing repair parts store. home décor ideas, maintenance, repair replacement parts
Designed for use on PVC pressure pipe and fittings up to 12". Flows freely and provides a thick layer of cement on the pipe. Helps to fill gaps in larger diameter pipe and loose fitting joints. NSF ce
SKU: 41660290
MFG: 018210-24
Shop more products by Harvey.

Biggest plumbing repair parts retail store to buy Solvents & Sealers

$11.69
In Stock
Request a Bulk Quote


Thank you for your quote request. We will be in touch.

DETAILS

DESCRIPTION

"P-12" PVC Cement

Designed for use on PVC pressure pipe and fittings up to 12". Flows freely and provides a thick layer of cement on the pipe. Helps to fill gaps in larger diameter pipe and loose fitting joints. NSF certified for use in potable water, sewer, and drain, waste and vent systems and should be applied at temperatures 40 degrees to 100 degrees fahrenheit. UPC listed. Meets requirements of ASTM D-2564. Dauber can.

TECHNICAL SPECIFICATION:

Harvey’s P-12 Heavy Duty Clear PVC Solvent Cement is recommended for solvent welding all schedules and classes of PVC pipe and fittings up to 12” diameter, and non-pressure applications up to 18” with interference fit. P-12 Heavy Duty Clear PVC Solvent Cement can be used for potable water, sewer and drain, waste and vent systems. This product is compliant with California South Coast Air Quality Management District (SCAQMD) Rule 1168 and Ozone Transport Commission (OTC) regulations for Volatile Organic Compound emission levels.

PHYSICAL/CHEMICAL PROPERTIES:

Appearance          Clear Liquid

Viscosity               min. 1600 cps @ 73° F ± 2° F

Density                 7.86 ± 0.2 lbs/gallon

Lap Shear Strength (minimum per ASTM Standards)

2 hours                 250 psi

16 hours               500 psi

72 hours               900 psi

Set Up Time

30° F to 50°          F 4 – 5 minutes

50° F to 70°          F 2 – 3 minutes

70° F to 90°          F 1 – 2 minutes

Shelf Life              3 years from manufacture date

INGREDIENTS (CAS Number)

  • Acetone (67-64-1)
  • Amorphous Silica (112945-52-5)
  • Cyclohexanone (108-94-4)
  • Methyl Ethyl Ketone (78-93-3)
  • PVC Resin (9002-86-2)
  • Tetrahydrofuran (109-99-9)

DIRECTIONS FOR USE:

Read all directions carefully before using this product.

  • Do not breathe vapors. Use only in well ventilated area. If forced air ventilation is used, be sure it does not cause a fire hazard from solvent vapors. If adequate ventilation cannot be provided, wear a NIOSH-approved respirator for organic solvents.
  • Do not use or store near heat, sparks, or flames. Do not smoke, eat or drink when using. Do not take internally. Vapors may accumulate in low places and may ignite explosively.
  • Store and use at temperatures between 40ºF and 110ºF. At temperatures outside of this range, special care must be taken to prepare good joints and prevent exposures to solvents.
  • Stir or shake before using; if jelly-like, don’t use. Keep container closed when not in use.
  • Avoid eye and skin contact - wear safety glasses with side shields and wear rubber gloves.
  • Do not thin.
  1. Square pipe ends and remove all burrs and dirt.
  2. Check dry fit of pipe and fitting. Pipe should easily go 1/3 of the way into the fitting. If the pipe bottoms, it should be snug.
  3. Use a suitable applicator at least 1/2 the size of the pipe diameter. For larger size pipe systems use a natural bristle brush or roller.
  4. Clean pipe and fitting with a listed primer.
  5. Apply liberal coat of cement to pipe to the depth of the socket; leave no uncoated surface.
  6. Apply a thin coat of cement to inside of fitting; avoid puddling of cement. Puddling can cause weakening and premature failure of pipe or fitting. Apply a second coat of cement to the pipe.
  7. Assemble parts QUICKLY. Cement must be fluid. If cement surface has dried, recoat both parts.
  8. Push pipe FULLY into fitting using a 1/4 turning motion until pipe bottoms.
  9. Hold pipe and fitting together for 30 seconds to prevent pipe push-out – longer at low temperatures. Wipe off excess.
  10. Allow 15 minutes for good handling strength and 2 hours cure time at temperatures above 60ºF before hydrostatic pressure testing up to 180 psi. Longer cure times may be required at temperatures below 60ºF or with pipe diameters over 3”. DO NOT TEST WITH AIR.

This product is not for use with caustic or acidic chemical solutions. Consult Technical Department for more information.

PRECAUTIONS:

Read all information carefully before using this product.

DANGER: EXTREMELY FLAMMABLE. VAPORS MAY CAUSE FLASH FIRES. MAY IRRITATE EYES AND SKIN. VAPOR HARMFUL. MAY IRRITATE RESPIRATORY TRACT AND CAUSE CENTRAL NERVOUS SYSTEM DEPRESSION. HARMFUL OR FATAL IF SWALLOWED.

WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

FEATURES

MFR: 018210-24
SKU: 41660290
UPC: 078864182101
Brand: Harvey

REVIEWS